OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all
instructions. Place instructions in a safe place for future
reference. Do not allow anyone who has not read these
instructions to assemble, light, adjust or operate the heater.
HEATSTAR High-Intensity Infrared Heaters
MODELS
Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
WARNING:
— Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityofthisorany
other appliance.
— WHATTODOIFYOUSMELLGAS
 • OpenWindows
 • DO NOT try to light any appliance.
 • DO NOT use electrical switches.
 • DO NOTuseanytelephoneinyourhouse.Immediatelycallyourlocalgassupplierfroma
  telephoneremotefromtheareaoftheleak.Followthegassupplier'sinstructions.
 • DO NOT touch any electrical switch; do not use any phone in your building.
 • Installationandservicemustbeperfomedbyaqualifiedinstaller,serviceagencyorthegas
supplier.
 • Ifyoucannotreachyourgassupplier,calltheFireDepartment.
Thisisanunventedgas-firedheater.Itusesair(oxygen)fromtheareainwhichitisused.Adequate
combustionandventilationairmustbeprovided.Refertopage5.
ENERCOGROUPINC.,4560W.160THST.,CLEVELAND,OHIO44135•866-447-2194
4000 & 8000 Models 9000 Models
HS4030 HS8070 HS9100
HS4040 HS9080 HS9120
HS8050 HS9090 HS9140
HS8060 HS9100S
WARNING: Improperinstallation,adjustment,alteration,serviceormaintenancecancauseproperty
damage, injury or death. Read the installation, operation, and maintenance instructions thoroughly before
installingorservicingthisheater.Forassistanceoradditionalinformationconsultaqualifiedinstaller,service
agency, or gas supplier.
E2
Enerco Group, Inc. |Gas-Fired Infra-Red Space Heaters Operating Instructions and Owner’s Manual
CONTENTS
GeneralInformation 3 ..........................................................
Clearances ........................................................................ 3
GasSupply 3 ........................................................................
GasPressure 4 .....................................................................
Electrical ........................................................................... 5
Thermostat&Location 5 ......................................................
Ventilation 5 ........................................................................
Operations ........................................................................5
CleaningInformation 5 ........................................................
Thermostat 6 .......................................................................
Troubleshooting 7 ................................................................
Connection diagram for flame rod current
for flame rectification systems ...................................... 8
Replacement parts ............................................................ 9
Control system replacement parts ....................................12
LANGUAGES
ENGLISH
Pages E1 — E16
SPANISH
Pages S1 — S16
FRENCH
Pages F1 — F16
`
WARNING: READTHISOWNER'SMANUAL
CAREFULLYANDCOMPLETELYBEFORETRYINGTO
ASSEMBLE,OPERATE,ORSERVICETHISHEATER.
IMPROPERUSEOFTHISHEATERCANCAUSESERIOUS
INJURYORDEATHFROMBURNS,FIRE,EXPLOSION,
ELECTRICALSHOCK,ANDCARBONMONOXIDE
POISIONING.
WARNING: WHENUSEDWITHOUTFRESH
AIR,HEATERMAYGIVEOFFCARBONMONOXIDE,AN
ODORLESSPOISONOUSGAS.OPENWINDOWANINCH
ORTWOFORFRESHAIRWHENUSINGHEATER.
WARNING: Thisheaterisequippedwitha
PILOTLIGHTSAFETYSYSTEM.DONOTTAMPERWITH
PILOTLIGHTSAFETYSYSTEM.
WARNING: Ifheatershutsoff,donotrelight
untilyouprovidefreshair.Ifheaterkeepsshuttingoff,
haveitserviced.Opendoorfor5minutes.
•Keepburnerandignitioncontrolclean.
•MaintainclearancesasshowninTable1oronheaterratetag.
•DONOTUSEMATCHOROTHERFLAMEFORLEAK
TESTING.
•DONOTEXCEED1/2PSIINLETPRESSURETOHEATER.
WARNING: Fuelsusedinliquefiedpropanegas
appliances, and the products of combustion of such fuel,
canexposeyoutochemicalsincludingbenzene,which
is know to the state of California to cause cancer and
causebirthdefectsorotherreproductiveharm,formore
informationgotowww.P65Warnings.ca.gov
CAUTION:
•Neverconnectgasvalveorthermostattolinevoltage
or a transformer.
•Iftheinfra-redcolorofthegridbecomesdullwhenthe
building furnace is operating, consult gas supplier on
correctgassupplypipingsizes.
•Thisheaterisforindoorinstallationonly!
Carbon Monoxide Poisoning:
Earlysignsofcarbonmonoxidepoisoningresemblethe
flu,withheadaches,dizziness,ornausea.Ifyouhave
thesesigns,theheatermaynotbeworkingproperly.Get
freshairatonce!Haveheaterserviced.Somepeopleare
moreaffectedbycarbonmonoxidethanothers.These
include pregnant women, persons with heart or lung
disease or anemia, those under the influence of alcohol,
and those at high altitudes.
DANGER:
CarbonMonoxidepoisoningmayleadtodeath.
NOTEGasketbindermaterialusedinthisheateras-
semblywilltemporarilyemitanodorand/orvapor.This
conditionwillclearupinapproximately20minutesand
thereafterwillnotreoccur.Refertopage5for
ventilation.
WARNING: THISPRODUCTCANEXPOSE
YOUTOCHEMICALSINCLUDINGLEADANDLEAD
COMPOUNDS,WHICHAREKNOWNTOTHESTATE
OFCALIFORNIATOCAUSECANCERANDBIRTH
DEFECTSOROTHERREPRODUCTIVEHARM.FORMORE
INFORMATIONVISITWWW.P65WARNINGS.CA.GOV
E3 Operating Instructions and Owner’s ManualEnerco Group, Inc. | Gas-Fired Infra-Red Space Heaters
1. GENERAL INFORMATION
a. Yourheatercomesfullyassembledandistestedat
the factory for proper gas and input as stated on
the name plate.
b. Beforeproceedingwiththeinstallation,besuretoin-
spectfordamages.Thefreightcompanythatdelivered
the heater must be notified of any damages prior to
installation.HEATSTARwillsendreplacementpartsfor
damagedpartsonlyafterreceivingasignedinspection
reporttoprovetheliabilityofthefreightcompany.
c. Do not attempt to operate heater with any other gas
than that indicated on the heater name plate.
d. Installationoftheheatermustconformwithlocal
building codes or, in absence of local codes, with
theNationalFuelGasCode,ANSIZ223.1/NFPA54.In
Canada,refertoCAN1-B146.1.
e. Plugged1/8”N.P.T.TestGageConnectionislocated
ontheHeaterGasControloraN.P.T.Connectionis
locatedontheoutsideoftheCastVenturi.
f. Forindoorinstallationonly.Notforuseinresidential
dwellings.NOTE:Aresidentialdwellingisadomicile
intended for use by one or more persons and that
includes one or more areas, such as those used for
cooking,eating,living,sleeping,orasanitaryfacility.A
residential dwelling does not include an attached and
detached garage, workshop, or outdoors.
2. CLEARANCES Minimum clearances to combustibles.
(Refer to Table 1)
Provideadequateclearancetocombustibles,Figure
1,betweencontrolendofheaterforservicing
andminimumontopandsidesforventilationand
combustion air supply.
Aminimumclearanceof8’abovefloorforpublic
garagesinaccordancewithANSI/NFPANo.88most
recenteditionorTable1;whicheverislarger.InCanada
refertoCAN1-B149.1InstallationcodesforGas
burning appliances.
Aminimumclearanceof10’fromthebottomof
heater to top of wing, or engine enclosure, where
aircraftarehoused,and8’abovefloorinotherareas
ofthehangerinaccordancewithANSI/NFPANo.409
mostrecentedition,orTable1;thelargerdimension
ofANSI/NFPANo.409orFigure1istobeused.In
CanadarefertoCCAB149-1-M91.
WARNING: MAINTAINCLEARANCESASSHOWN
INFIGURE1ORONHEATERNAMEPLATE,INGARAGE
INSTALLATIONSWHEREPARKEDVEHICLESARE
DIRECTLYBELOWTHEHEATER.
3. SUSPENSION
Heaterhasfourmountingholes,twooneachend,for
attaching rod or angle iron brackets and shall be safely
andadequatelyfixedinpositionindependentofgas
andelectricsupplylines.RefertoFigures4,5,and7on
pages13and14forrecommendedsuspensions.
4. GAS SUPPLY
Provideadequategassupplyforratedinputofeach
heaterusingAmericanStandardInstallationofgas
pipingandgasappliancesinbuildingANSI/223.1a/
NFPA54Pamphlet,TableC-3showscapacityofpipe
of different diameters and lengths in cubic feet per
hourforNaturalGaswithpressuredropof0.3inches
specifygravityof0.60.ForliquefiedPetroleumGas
(LP)capacityrefertoTableC-3andC-15ofthesame
pamphlet.Forrecommendedheatergasconnection
refertoFigureNo.5,Page15.InCanadarefertoCAN
1-B149.1,andCSAB63.
Ifgaslinesaretobepressuretestedwithcompressed
air,disconnecteachheatertopreventcontroldamage
andcapoutlets.Afterreconnectingallheaters,purge
gas lines of air and check all connections for leaks us-
ing soap solution.
WARNING: DONOTUSEMATCHOROTHER
FLAMEFORLEAKTESTING.
5. PIPING REQUIREMENTS
Allpipinginstalledmustcomplywithlocalcodesandordinances
orwiththeNationalFuelGasCode,ANSIZ223.1(NFPA54),
whichevertakesprecedence.Wheninstallingpiping,thefollowing
requirementsmustbetakenintoconsideration:
• Usenewproperlyreamedblackpipefreefromchips.
• Applyagoodqualitypipecompoundtoallmalethreads
priortoassembly.IfL.P.gasisthefuel,ensurethatpipe
compoundisresistanttoL.P.gas.DONOTUSETEFLON
™ tape.
• Priortoinstallation,applypipecompoundtoallmale
threadsasshowninFigure1
• Malethreadsonpipetobeinstalledintogasvalveshall
meettherequirementsofFigure2.Threadslongerthan
thoseshowninthefiguremaycausegasvalvedistortion
and malfunction.
• Asedimenttrapmeetingthetypicalrequirementsof
Figure3shallbeinstalledinthelinetothegasvalve.
• Adedicatedshutoffvalvefortheheatermustbein-
stalled in the gas supply line.
Figure 1. Pipe Compound Application
USE MODERATE AMOUNT OF PIPE DOPE
LEAVE FIRST 2 THREADS BARE
¾3/4”MAXIMUMTHREADLENGTH
 ½”BLACKPIPE
TOGASVALVEBODY
Figure 2.
Gas valve
connection
requirements

Produktspecifikationer

Varumärke: HeatStar
Kategori: Värmare
Modell: HS9120