Master MAC-121CDP Bruksanvisning

Master Fläkt MAC-121CDP

Läs nedan 📖 manual på svenska för Master MAC-121CDP (24 sidor) i kategorin Fläkt. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/24
MODEL NUMBER:
MAC-121CDP
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
This blower is designed to dry damp surfaces quickly. This blower produces a high-volume flat air
column that increases evaporation. For best results, be sure to install blower so all damp surfaces are
exposed to the air flow.
RISK OF EXPLOSION! For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors.
DANGER
USE THIS BLOWER ONLY AS DESCRIBED IN THIS MANUAL. ANY OTHER USE NOT
RECOMMENDED BY THE MANUFACTURER MAY CAUSE FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS.
WARNING
User’s Manual &
Operating Instructions
LOW PROFILE
CARPET DRYER
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
© 2018 Pinnacle Climate Technologies, Inc. MABA-405
Locating Your Serial Number:
Your serial number can be found on the blower’s Rating Label. It will begin with the letters “LX” followed by 9 digits.
For Example: LX123456789. Have your Serial Number ready before calling customer service at 800-641-6996.
NEVER LEAVE BLOWER UNATTENDED WHILE OPERATING OR
WHILE CONNECTED TO A POWER SOURCE
© 2018 Pinnacle Climate Technologies, Inc. Low Profile Carpet Dryer User’s Manual
TABLE OF CONTENTS
Safety Information........................................................1-2
Specifications...................................................................3
Features.............................................................................3
Operation..........................................................................4
Maintenance....................................................................4
Troubleshooting Guide..................................................5
Warranty.............................................................................6
1
SAFETY INFORMATION
Look for this icon throughout the manual for helpful tips on how to assemble,
use and clean your Carpet Dryer.
To Reduce The Risk Of Electric Shock, Do Not Expose To Water Or Rain.
WARNING
THIS IS NOT A TOY! Keep out of reach of children. This blower is intended for use
by only qualified persons.
WARNING
RISK OF ELECTRIC SHOCK! TAKE PRECAUTIONS TO PREVENT INJURY.
WARNING
RISK OF INJURY! DO NOT MOVE BLOWER WHILE IT IS OPERATING.
WARNING
RISK OF INJURY! Keep hair, loose clothing, fingers and all body parts away from air
inlet and outlet.
WARNING
In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this ap-
pliance must not be supplied through an external switching device, such as a timer, or
connected to a circuit that is regularly switched on and o by the utility.
CAUTION
RISK OF ELECTRIC SHOCK OR INJURY. Do not route cord under carpeting, Do not
cover cord with throw rugs, runners, or similar coverings. Do not route cord under
furniture or appliances. Arrange cord away from the trac area where it will not cause a tripping
hazard. Do not operate any blower with a damaged cord or plug, or after blower malfunctions, or has
been dropped or damaged in any manner. Discard blower, or return to authorized service facility for
examination and / or repair.
WARNING
RISK OF ELECTRICAL SHOCK. Connect to properly grounded outlets only. Do not
insert or allow foreign objects to enter any ventilation or exhaust opening as this
may cause an electric shock or fire, or damage the blower. Unplug blower before performing any
maintenance or when not in use.
WARNING
Automatically Operated Device - To Reduce The Risk Of Injury, Disconnect From
Power Source Before Servicing.
CAUTION
Keep Out of Dangerous Areas Do not operate the unit near dangerous areas such
as fire, gas, fumes, or hazardous materials. Doing so might result in injuries to the
operator or those around the unit.
WARNING
This product contains chemicals, including lead, which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov.
WARNING
NEVER LEAVE BLOWER UNATTENDED WHILE OPERATING OR
WHILE CONNECTED TO A POWER SOURCE
© 2018 Pinnacle Climate Technologies, Inc. Low Profile Carpet Dryer User’s Manual
SAFETY INFORMATION (CONT.)
This blower is designed to dry damp surfaces
quickly. This blower produces a high-volume,
flat air column that increases evaporation. For
best results, be sure to install blower so all damp
surfaces are exposed to the air flow.
Before operating this blower, be sure that
you know how to switch the blower o in an
emergency.
ALWAYS use only the electrical power (voltage and
frequency) specified on the model plate of the blower.
ALWAYS use only three-prong, grounded outlet.
ALWAYS use only 14 AWG or higher gauge extension
cord.
ALWAYS unplug the blower when not in use.
ALWAYS install the blower so that it is not directly
exposed to water spray, rain, dripping water, or wind.
ALWAYS disconnect blower from power source
when not in use.
Use this blower only in the matter intended by the
manufacturer. If you have any questions, contact
Customer Service at 800-641-6996.
Do not operate any blower with a damaged cord
or plug. Discard blower or return to an authorized
service facility for examination and/or repair.
If the blower is damaged, do not use it. The
blower must be serviced by a qualified person or
service agent.
When servicing or replacing a component
requires the removal or disconnection of a safety
device, the safety device is to be reinstalled
or remounted as previously installed before
operating this blower.
NEVER pull or carry the blower by the
power cord.
NEVER block the air inlet (rear) or air outlet (front)
while in operation.
NEVER insert any objects through the blower
guards.
NEVER use to ventilate harmful, explosive,
flammable, or volatile gases, fumes, or substances.
This blower produces a strong, constant stream of
air. Before operating blower be sure there are no
unsecured materials that can be blown about the
stream of air.
Minimum Distance From Blower
MAC-121CDP
Front 5 ft. (1.5 m)
Sides 3.2 ft (1 m)
DO NOT USE TO VENTILATE
HARMFUL GASSES OR VAPORS.
DANGER
RISK OF ELECTRIC SHOCK!
WARNING
2
CAUTION – RISK OF ELECTRIC SHOCK
DO NOT OPEN BLOWER SHELL
NO USER-SERVICEABLE S INSIDEPART
To Reduce The Risk Of Electric
Shock And Injury To Persons, Do
Not Use In A Window.
WARNING
To reduce the risk of electric
shock, connect only to an outlet
provided with a ground fault interrupting
device.
WARNING

Produktspecifikationer

Varumärke: Master
Kategori: Fläkt
Modell: MAC-121CDP

Behöver du hjälp?

Om du behöver hjälp med Master MAC-121CDP ställ en fråga nedan och andra användare kommer att svara dig




Fläkt Master Manualer

Fläkt Manualer

Nyaste Fläkt Manualer